Fiberglass Insulated Wire

  • Can be impregnated with different varnishes.
  • The insulation is mechanically strong and can be used in high voltage applications safely.

Rectangular Cross Section

PropertiesCopper ValuesAluminum ValuesUnit
Width3.00 ≤ W ≤ 30.003.00 ≤ W ≤ 30.00mm
Thickness1.00 ≤ T ≤ 12.001.00 ≤ T ≤ 12.00mm
Cross Section3.00 ≤ CS ≤ 200.003.00 ≤ CS ≤ 200.00mm

Round Cross Section

PropertiesCopper ValuesAluminum ValuesUnit
Diameter2.00 ≤ 0 ≤ 10.002.00 ≤ 0 ≤ 10.00mm
Cross Section3.00 ≤ CS ≤ 100.003.00 ≤ CS ≤ 100.00mm2

Conductivity Values

Properties
Copper ValuesAluminum ValuesUnit
Enamali insulation increase
0.06 ≤ X ≤ 0.120.06 ≤ X ≤ 0.12mm
Fiberglass insulation increase
0.12 ≤ X ≤0.20( 1.Kat)
0.20 ≤ X ≤ 0.50(1.Kat)
0.12 ≤ X ≤0.20( 1.Kat)
0.20 ≤ X ≤ 0.50(1.Kat)
mm
Insulation material
%100 Cam-Elyaf ve/veya %100 Polyester film emaye (180◦C)%100 Cam-Elyaf ve/veya %100 Polyester film emaye (180◦C)
Varnish
Epoxy( 155◦C )
Polyesteremine( 180◦C )
Epoxy( 155◦C )
Polyesteremine( 180◦C )
Breakdown Voltage
IEC 317-0-4
Or customer specification
IEC 317-0-4
Or customer specification
kv

Standards

ÖZELLİKLERCopper ValuesAluminum ValuesUnit
IEC, DIN, TSIEC 317-31…33 IEC 317-0-4, IEC 317-0-6
IEC 851-1..6( for testing)
Customer specification
IEC 317-31…33 IEC 317-0-4, IEC 317-0-6
IEC 851-1..6( for testing)
Customer specification